Highest efficiency in a spray booth is always attained when the capacity, size and other specifications are most suited to the kind of work to be performed.
The following factors are important while selecting the most appropriate booth for a specific coating component.
Models | Dimension in (mm) | Exhaust Blower | Pump | Tube Lights | ||||
W/w | D/d | H/h | Capacity M3/hr |
Motor Rating |
Cap. | Watts | Nos. | |
DynaSpary-WW15 | 2000/1500 | 2850/1500 | 3600/2100 | 1 x 6800 | 1 x 3.12 KW | 1.5 KW | 2 x 36 | 1 |
DynaSpary-WW21 | 2600/2100 | 2850/1500 | 3600/2100 | 1 x 7900 | 1 x 3.70 KW | 2.25 KW | 2 x 36 | 1 |
DynaSpary-WW30 | 3500/3000 | 3250/1800 | 3600/2100 | 2 x 6800 | 2 x 3.12 KW | 3.75 KW | 2 x 36 | 2 |
DynaSpary-WW36 | 4100/3600 | 3250/1800 | 3600/2100 | 2 x 7900 | 2 x 3.70 KW | 3.75 KW | 2 x 36 | 3 |
Note
(i) W x D x H : Overall Width x Depth x Height
(ii) w x d x h : Working Width x Depth x Height
Larger sizes are available against specific requirements.
Optional: Flameproof accessories are available against specific requirements.
Also available in stainless steel construction.